600A
Digital Clamp-on Multimeter
(2 models available)
|
ACD-10 PLUS Clamp-on
Multimeter
AM-ACD-10PLUS
$89.95 |
|
|
ACD-10 TRMS-PLUS
True RMS
Clamp-on
Multimeter
AM-ACD-10TRMS-PLUS
$109.95 |
|
Optional Accessories:
|
Amprobe
ACD-10 PLUS / ACD-10 TRMS-PLUS

600A
Digital Clamp-on Multimeters
w/ Unique Thin Jaws
Amprobe’s ACD-10 PLUS meters offer
thinner jaws over standard clamp
meters,
allowing
access to tight measurement areas and still accommodating
conductors up to 1 inch.
Both meters also measure Capacitance and Frequency.
Frequency is measured by either jaws or test leads -
Very versatile clamp Multimeters.!
True RMS version (ACD-10 TRMS-PLUS) for
noisy measurement environments for a more accurate reading.
- AC & DC Voltage to 600V
- AC Current to 600A
- Thin Jaws, only 10mm (0.4”) thick
- Resistance to 40MΩ
- Continuity Buzzer
- Capacitance to 3000 uF
- Frequency measurement
- In rush current
- Hold & Maximum reading functions
- Accommodates conductors up to 26mm (1.02”) in diameter
- Auto ranging
- Auto power off
- Rubber over-molded case
- Overload protected
- TRMS Measurement (ACD-10 TRMS-PLUS)
- Included Accessories: Test leads,
battery installed, soft carrying pouch, and users manual
Specifications:
|
Size: |
|
190 x 63 x 32 mm (7.4 x 2.5 x 1.3 in |
|
Weight: |
|
139 gm approx |
|
Safety: |
|
Meets EN61010-2-032, UL61010B-2-032, IEC61010-1 2nd
Ed., EN61010-1 2nd Ed., UL61010-1 2nd Ed. CAT III-600 Volts ac & dc;
Pollution degree : 2 |
|
Display: |
|
3-3/4 digits 4000 counts LCD display |
|
Update Rate: |
|
3 per second nominal |
|
Polarity: |
|
Automatic |
|
Operating Temperature: |
|
°C to 40 °C; < 80% RH for temperature up to 31 °C
decreasing linearly to 50% RH at 40 °C |
|
Altitude: |
|
Operating below 2000m; Indoor use |
|
Storage Temperature: |
|
-20 °C to 60 °C, < 80% RH (with battery removed) |
|
Temperature Coefficient: |
|
nominal 0.15 x (specified accuracy)/°C @(0 °C ~ 18 °C
or 28 °C ~ 40 °C) |
|
Low Battery: |
|
Below approx. 2.4V |
|
Power Supply: |
|
3V coin battery IEC-CR2032 |
|
Power Consumption: |
|
2.8 mA typical except that 3.3 mA typical for ACA
function |
|
APO Timing: |
|
Idle for 30 minutes |
|
APO Consumption: |
|
5 μA typical |
|
Jaw opening & Conductor diameter: |
|
max 26 mm (Approx 1 inch) |
|
Special Features: |
|
30ms Max Hold; Data Hold; Relative Zero mode |
Optional Accessories:
|
Orders over $200.00 ship
FREE
to 48 states |
|
ELS2A
AC Line
Splitter
LE-AM-ELS2A
$13.95 |
|
|
Amprobe
ELS2A AC Line Splitter
- Measures current without splitting AC line cords
- Two
measurement loops for increased sensitivity, X1 and
X10
- Built-in voltage measurement points to check for
voltage sags and surges
- Rated for 120V, 15Amps
|
more Clamp-On Multimeters
|